Voltage Drop of Device: Less than 0.5V at ID = 20A
Vibration Durability: Based on KES D-C454, Section 7.4.1
Durability Test: Connected to the blower assembly in real conditions, must pass 1000 hours at 8 determined speeds. After the test, it must pass insulation resistance, maximum current, and short-circuit resistance tests.
Thermal Shock: Pass 10 cycles based on KES D-C454, Section 7.5.1
Terminal Pushing Force: Apply 10 kgf to the terminals under the conditions specified in KES D-C454, Section 7.3.5
Setting Points for Blower Motor (at Full Cold, Fresh, Face with 13.5V supply input on Auto Control Panel):
L1: 4.7 ± 0.2V
L2: 5.2 ± 0.2V
L3: 6.0 ± 0.2V
L4: 6.9 ± 0.2V
L5: 8.5 ± 0.2V
L6: 9.8 ± 0.2V
L7: 11.5 ± 0.2V
L8: 13.5 ± 0.2V